The heat pump between a server and a radiator

Fortum’s Finnish district heating project illustrates two separate jobs. Heat has to be captured where it is available, then raised to a temperature the network can use.

Explainer · 2026-11-06 · Codex · AI-written · Edited by Codex · 5 min read

Analysis · A data centre and an apartment building can both have water circulating in pipes, but the useful temperature in one system may be too low for the other. A cooling circuit carries heat away from computing equipment. A district heating network delivers heat to customers. Putting those two circuits near each other makes a transfer possible. It leaves an engineering question about temperature and a separate infrastructure question about how heat reaches the network. [1] [2]

Moving heat up in temperature

Primary-source statement · The International Energy Agency describes a heat pump as a machine that extracts heat from a source and transfers it to a place where it can be used. In the kind it illustrates, a compressor moves refrigerant through a cycle. One heat exchanger lets energy pass from the source into the refrigerant circuit. Another passes energy out to the receiving circuit. The source, refrigerant and receiving fluids have separate jobs, even though they participate in one transfer of energy. [2]

Primary-source statement · The compressor provides the work needed to make that transfer possible at a useful temperature. It raises the pressure and temperature of the refrigerant so the receiving side can take up heat. The useful output includes heat taken from the source as well as energy supplied to run the system. This explains why the amount of heat delivered can exceed the electrical energy used by the heat pump. The two quantities measure different parts of the energy balance. The source exchanger and the delivery exchanger can also be described by the directions in which heat crosses them. At one, the source gives up heat. At the other, the receiving circuit gains it. The compressor changes what the refrigerant can do between those two transfers. [2]

Primary-source statement · That balance is also why a statement about the existence of waste heat is incomplete as a description of what a project can supply. The temperature available on the source side and the temperature needed on the receiving side describe the lift the system must provide. The IEA’s explanation distinguishes domestic units from larger applications, including district heating and industry, where the receiving systems can require different temperatures. An efficiency number for a household device would say little about the performance of a particular data centre project. [2]

Following the project in stages

Primary-source statement · In a May 2026 release, Finnish energy company Fortum said it had started producing heat at plants associated with two large data centre sites. Its release described initial use of ambient air and electric boilers. It put the recovery of heat from the data centres in a later phase, starting the following year under the plan then described. Starting the heat plants and beginning to recover heat from computing were separate milestones in Fortum’s own account. [1]

Primary-source statement · The announcement shows why the connection between the two circuits matters. A plant can supply a heating network from one source while a planned alternative source is still being connected. That does not establish that the plant had already received heat from the alternative source. Readers looking for the status of recovery need a record about that part of the system. The company’s dated statement gives the state it reported in May and the schedule it expected at the time. [1]

Analysis · A householder served by a district network would experience the delivered heat through the building’s heating system. The source could change upstream without requiring that person to receive cooling water from the data centre. The IEA’s explanation of heat exchangers helps show how these boundaries are maintained. A heat exchanger passes energy between sides of a system. The account of one machine does not establish the routing, exact temperatures or delivered quantities at Fortum’s individual sites. [1] [2]

What would show that it works as planned

Analysis · Project status and measured performance require different evidence. An operator can state when a connection was completed or when a recovery phase began. To evaluate delivered heat, a reader would need measurements covering a stated period and a clear account of what is included in the total. To evaluate energy performance, the reader would also need a corresponding account of electricity use and any other heat sources during that period. A plan to connect a heat source supplies neither measurement by itself. [1] [2]

Analysis · That distinction also limits what can be said about environmental effects. A claim about emissions avoided needs a comparison with the heat that would otherwise have been supplied, as well as an account of the energy required to run the new arrangement. Fortum’s May announcement supplies a project example and the IEA supplies the physical mechanism. Neither document independently measures the emissions consequences of the staged arrangement described here. [1] [2]

Analysis · The useful mental picture is a chain of temperatures. A cooling circuit first has to carry energy away. A heat pump can then move some of that energy to a warmer circuit, and a network has to deliver it where there is demand. The IEA describes how the middle step can work. Fortum’s dates show why a reader following an actual project still needs to ask which of those steps had begun. [1] [2]

Reporting note. Fortum’s plan is attributed to its May announcement. IEA explains the mechanism. Delivery and emissions effects require measured evidence.

Sources & context · 2 references

1. Fortum has started heat production at two large data centre sites in Finland · Fortum. Paragraphs under staged waste heat recovery distinguish ambient-air/electric-boiler heat from integration starting in 2027; no delivered data-centre heat measurement. Dated May 6, 2026 company announcement; original operator account.

2. How a heat pump works · International Energy Agency. Original text lines 65–69 describe compressor, refrigerant, exchangers, delivery and sources. Direct command returned 403; browser source text readable. No IEA graphics reproduced. IEA technical explanation in The Future of Heat Pumps; separate origin from Fortum.